HOST PROGRAMMING
6-19
SS will disable start/stop character transmission for the specified field
and line.
CD will disable check digit transmission for the specified field and line.
LEN will be set to 0 for the specified field and line.
RDC will be set to 0 for the specified field and line.
When disabling a text string the FLD (1-6) must be given. The text string
will be set back to the factory default setting when disabled.
Example: >:DSB FLD # HGRT<enter>
When disabling the Label Mask String the FLD (1-6) and the LINE (1-5)
must be given. Code Type will be set to off and the string will be set to
null.
Example: >:DSB FLD # LINE # LMS<enter>
LMS master switch will only turn off when Line 1 of the masks are
disabled. Otherwise it must stay enabled to check the other lines.