Product Reference Guide 4-7
Other Scale Reporting
- 0 - Off
Cannot zero at power- up or
weight remains on scale for
more than 4 minutes or
weight has not returned to
zero between POS weight
requests
a
.
- Check debris chutes.
- Verify that the weigh platter moves
freely.
- Remove item(s) from scale
- Press Scale Zero Push Button for
more information.
- If the scale still fails to zero, recali-
brate the scale.
__--- Off
Over- and underweight con-
ditions.
- Remove all weight from scale
- Rezero.
a. This is a configurable feature.
Table 4-2. Scale Error Reporting
Remote
Display
Scale Status
Lamp
Problem
Description
Action Required
Seitenansicht 82